XY-TR01 temperature and humidity control module with display

XY-TR01 temperature and humidity control module with display

19,800.00

In stock

SKU: 2304 Category:

The temperature function is as follows:

1. Automatic recognition of working mode:  

The system automatically recognizes the working mode according to the start temperature / stop temperature;

Starting temperature> stop temperature, the cooling mode ‘ C  ; the starting temperature <stop temperature, the heating mode ‘ H ‘;

2. Cooling mode:  

When the detection temperature ≥ the starting temperature, the relay is turned on, the red indicator light is on, and the refrigeration equipment starts to work;

When the detected temperature is less than or equal to the stop temperature, the relay is turned off, the red indicator light is off, and the refrigeration equipment stops working;

3. Heating mode:  

      When the detection temperature is less than the start temperature, the relay is turned on, the red indicator light is on, and the heating device starts to work;

     When the detected temperature is greater than or equal to the stop temperature, the relay is closed, the red indicator light is off, and the heating device stops working

4. Temperature correction function   OFE (-10.0 ~ 10.0  ) :

     When the system works for a long time, there may be deviations. Through this function, the actual temperature = measured temperature + calibration value;

How to set the start / stop temperature:

1. In the running interface, long press the ‘ TM + ‘ key for more than 3 seconds to enter the startup temperature setting interface. The test can modify the parameters through the TM + TM- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save;  

2. In operation interface, press ‘ the TM- ‘ key 3 or more seconds to enter stop temperature setting screen, the test can TM + TM- modified parameter key until the parameter modification, wait 6s withdrawn immediately save;  

 

Humidity functions are as follows:

1. Automatic recognition of working mode:  

The system automatically recognizes the working mode according to the start humidity / stop temperature;

Start humidity> Stop humidity, dehumidification mode ‘ D  ; start humidity <stops humidity, the humidification pattern ‘ E  ;

2. Dehumidification mode:  

When detecting humidity ≥ start humidity, the relay is turned on, the green indicator light is on, and the dehumidification equipment starts to work;

When the detected humidity is less than or equal to the stop humidity, the relay is closed, the green indicator light is off, and the dehumidification equipment stops working;

3. Humidification mode:  

     When the detected humidity is less than the start humidity, the relay is turned on, the green indicator light is on, and the humidifying device starts to work;

    When detecting humidity ≥ stop humidity, the relay is turned off, the green indicator light is off, and the humidifying device stops working

4. Humidity correction function RH (-10.0 ~ 10.0 ℃ ) :    

   The system works for a long time, and there may be deviations. Through this function, the actual humidity = measured humidity + calibration value;

 

How to set start / stop humidity:

1. In operation screen, press ‘ RH + ‘ button 3 or more seconds to enter start humidity setting screen, the test can RH + RH- change the parameter, the parameter to be modified is completed, wait 6s withdrawn immediately save;  

2. In operation interface, press ‘ RH- ‘ key 3 or more seconds to enter stop humidity setting interface, can be tested by RH + RH- change the parameter, the parameter to be modified is completed, wait 6s withdrawn immediately save;  

Operation interface description:

    Working mode display. After the start temperature / humidity, stop temperature / humidity and other parameters are set, the current mode ( “H/C” , “E/d” ) will be displayed in front of the temperature / humidity ;

    When any relay is turned on, the upper left corner of the interface displays “OUT” . If the temperature relay is turned on, the temperature operating mode “H/C” will flash to indicate a reminder; if the humidity relay is turned on, the humidity operating mode “E” /d” to show reminders;

Other functions:

1. Remote parameter reading / setting:  

     Through UART parameters such as start temperature / humidity, stop temperature / humidity, temperature / humidity correction can be set;  

2. Real-time reporting of temperature / humidity:  

     If the temperature / humidity report function is turned on , the product will detect the temperature / humidity and the status of the relay at 1s intervals and transmit it to the terminal via UART to facilitate data collection;

3. Relay enable ( open by default ) :  

If the relay enable is turned off, the relay remains disconnected;

How to modify the temperature / humidity correction value:

1. In the running interface, double-click the’TM+ ‘ key to enter the correction value setting interface; the lower line displays the correction value type, and the upper line displays the specific value; ( OFE : temperature correction value RH : humidity correction value)    

2. At this time, by a short press ‘ the TM- ‘ key, the handover parameter to be modified, by RH + RH- key to modify specific values; long press short press;  

3. After the parameter modification is completed, double-click the’TM+ ‘ key to exit the correction value setting interface and save the data;  

 

How to turn on / off the relay enable switch:

      In operation interface, press  the TM- ‘ key to turn on or off temperature Relay enabled (ON : Open OFF : closed ) , return to the operation screen, if the temperature of the relay is turned off, the temperature of the symbol ‘℃’ to blink Reminder.

      In operation interface, press  RH- ‘ key, to open or close humidity Relay enabled (ON : Open OFF : closed ) , the return to operation of the interface, the relay is turned off if the humidity, the humidity symbol ‘ % ‘ to blink Reminder. 

 

 

Serial port control (single-chip TTL level communication)

 

Communication standard : 9600bps  data bits : 8 
Stop bit : 1 
Check digit : none 
Flow control : none 

Serial command

Description

start

Start temperature report

s

Stop temperature reporting

read

Read setting parameters

T:ON

Temperature relay enable open

T:OFF

Temperature relay enable close

H:ON

Humidity relay enable open

H:OFF

Humidity relay enable close

TS:XX.X

Set start temperature

(-20.0~60.0)

TP:XX.X

Set stop temperature

(-20.0~60.0)

HS:XX.X

Set start humidity

(00.0~.0)

HP:XX.X

Set stop humidity

(00.0~100.0)

TC:XX.X

Set temperature calibration

(-10.0~10.0)

HC:XX.X

Set humidity calibration

(-10.0~10.0)

 

 Description of temperature and humidity data upload format:

Temperature format: working mode (H/C), temperature value, temperature relay status;

Humidity format: working mode (E/D), humidity value, humidity relay status;

H, 20.5 ℃ , CL: heating working mode, the current temperature is 20.5 degrees, and the temperature relay is off;

D, 50.4%, OP: Dehumidification working mode, the current humidity is 50.4% , and the humidity relay is in the state of closing;